Kosmos 535 ET is a digital stationary diagnostic X-ray device with a remotely controlled table-stand and a dynamic flat-panel X-ray detector. The distinctive feature of the Kosmos 535 ET devices is their compactness with the possibility of conducting X-ray and X-ray examinations, as well as tomosynthesis.
Kosmos 535 ET device can take a position up to vertical (+90°/-90°) and has a variable tabletop height. The X-ray emitter can change the angle of inclination in the range from -40° to +40° relative to the tabletop perpendicular. The table is equipped with two screening rasters with a focal length of 120 cm and 180 cm. As the source/receiver distance changes, the rasters are changed automatically.
Kosmos 535 ET devices allow standard X-ray examinations to be performed in various patient positions – lying or sitting on the imaging table, or standing, with the device in a vertical position. The device comes with a footrest that can be used to examine a patient in a sitting position, and the small distance from the floor to the footrest with the table in a vertical position allows for examinations of the lower extremities under load.
The operator’s workstation has two monitors – a high-brightness 18″ black-and-white monitor is located in the procedure room on a trolley, and a color 19″ monitor is installed near the control panel. The devices are fully compatible with the DICOM 3 medical image transmission standard and are easily integrated into the existing hospital LAN. In the absence of a hospital LAN, it is recommended to equip this device with a specialized software/hardware “Medical Diagnostic Station” complex.
| General specifications | |
|---|---|
| Generator power, kW | 50 |
| Maximum anode current, mA | 630 |
| Anode voltage range, kV | 40 – 150 |
| Workstations qty | 1 (remote controlled tripod table) |
| Automatic exposure control | Exposure meter available |
| Table top tilt range | +90°/-90° |
| Emitter arm tilt angle range | +40°/-40° |
| Emitter specifications | |
| Anode heat capacity, kHU | 300 |
| Anode type | Rotating |
| Anode rotation speed, rpm | 3000 / 10000 |
| Anode tilt angle, degrees | 12,5° |
| Focal spots, mm | 0,6 / 1,2 |
| X-ray diaphragm (collimator) | Remotely adjustable |
| X-ray diaphragm rotation angle | +45°/-45° |
| Tomosynthesis specifications | |
| Maximum cutting height, cm | 35 |
| Cutting height step, mm | 1 |
| Emitter movement speed, deg/s | 4,0 |
| Tomosynthesis angle | 20°, 40°, 60° |
| Emitter movement direction | Right to left or left to right |
| Tomosynthesis duration, sec | 5 sec for 20° 7,5 sec for 40° 10 sec for 60° |
| Image receptor specifications | |
| X-ray image receptor type | Dynamic flat panel wired detector |
| Photomatrix material | a-Si (amorphous silicon) |
| Scintillator material | CsI (Cesium-Iodine) |
| Detector size | 43х43 cm |
| Pixel size | 148 microns |
| Gradational resolution | 16 bit, 65536 gray values |
| Operator workstation specifications | ||
|---|---|---|
| Operator workstation type | Standalone | |
| Display | 18” black and white | 19” color |
| Resolution, pixels | 1280 х 1024 | 1280 х 1024 |
| Brightness, cd/m2 | 1500 | 450 |
| User interface language | Russian | |